Detection

CBRN-SPRINTER

Cargo/Vehicle Inspection System

CBRN-SPRINTER Vehicle
Thumbnail 1
Thumbnail 2
Thumbnail 3
Scroll ↓

The CBRN vehicle is consisting of a basic chassis transformed and partitioned into the driver's area, personnel transport area, laboratory area, equipment transport area, and a trailer custom built to carry the tents (decontamination and logistic), accessories for the tents, and other decontamination equipment.


An optical and acoustic warning system will be fitted on the roof of the vehicle, consisting of a LED lightbar in front of the roof, with siren. The colour of the lightbar will be provided by the customer and determined by the laws of the customer's country. In the rear of the vehicle's roof, there will be a beacon. The front grill will also be fitted with forward flashing LED lights.


A turnable and tiltable remote-controlled light projector will be mounted on the front end of the roof. There will also be a surrounding lighting system to provide more light around the vehicle in poor light conditions.


To ensure safety conditions when driving the vehicle with the rear, a buzzer and a rear-view camera will be mounted. Also, to enforce safety of the traffic ahead, a traffic monitoring camera with recording possibilities will be mounted below the rear-view mirror, facing forward.


Key Features:

  • Custom-designed chassis with multiple functional areas
  • Integrated optical and acoustic warning system
  • Remote-controlled lighting system for various conditions
  • Advanced safety features including cameras and monitoring systems
  • Custom-built trailer for decontamination equipment transport
  • Laboratory area for on-site analysis
  • Personnel transport capability for field operations
  • Equipment storage and transport solutions

This specialized vehicle is designed for CBRN (Chemical, Biological, Radiological, Nuclear) response operations, providing comprehensive capabilities for detection, analysis, and decontamination in emergency situations.


The vehicle's modular design allows for flexible configuration based on mission requirements, making it suitable for various scenarios from industrial accidents to military operations.


Deployment Options:

The CBRN-SPRINTER can be deployed as a standalone response unit or integrated into larger emergency response systems. Its mobility allows for rapid deployment to incident sites, while its comprehensive capabilities ensure effective CBRN threat management.


Training and Support:

Comprehensive training programs are available for operators, ensuring optimal use of the vehicle's capabilities. Technical support is provided to address any operational issues and maintain readiness.

Technology Gas Chromatography/Mass Spectrometry (GC/MS)
Dimensions (L x W x H) 33.7 x 33.7 x 40 cm (includes batteries, carrier gas, and vacuum system)
Weight 16.3 kg (includes batteries, carrier gas, and vacuum system)
Operating Temp / Humidity 0 to 40 °C
Storage Temp -25 to 55 °C
Decontamination Sealed for Survey Mode operation in hot-zone; IP65-rated enclosure is dust-tight and spray-resistant
Power Supply 100-240V 50-60Hz (220 W max); 19V (DC); 2 x #2590 @ 15V Li Ion batteries (1 included)
Battery Life 4 hrs in Survey Mode, 2 hrs in Confirmation Mode; hot swappable
Start Up Time 15 minutes to full operation from cold
Calibrant Onboard FC-43 (Perfluorotributylamine)
Carrier Gas On-board helium; external helium connector, automatic switching (Hydrogen capable)
Display 9" Multitouch Color Display (1280x720 WVGA; 1300 nits brightness)
Alerts Audible and Visual (Touchscreen and Handheld Probe)
Software GSS Touch; multiple user levels
Communication 2 x USB 2.0, Bluetooth 4.0, WiFi 802.11n, Ethernet via USB, integrated GPS
Data Storage Internal 256GB SSD
Training Requirements 2 hours basic operation; 8 hours expert user
Sample Phase Solid, liquid, and vapor
Threats Detects and identifies explosives, narcotics, CWAs, TICs, environmental pollutants, and other chemicals
Standard Reference Database NIST/EPA/NIH Mass Spectral Library
Sampling & Analysis Full identification in 4-15 mins for most chemicals; near real-time in Survey Mode
Mass Analyzer Type Linear quadrupole mass filter
Mass Range / Resolution 15-515 m/z; 0.7 amu @ FWHM
Ionization Type / Source Electron Impact Ionization; non-radioactive ionization source
Detector Electron Multiplier
Vacuum System Self-contained miniature turbomolecular & diaphragm pumps
Dynamic Range 7 decades
Detection Limit PPM – PPT
LTM-GC Column DB-5MS (15 m x 0.18 mm x 0.25 μm); others available
Temperature Range Programmable 40 to 300 °C; ramping of 100 °C/min
  • Technology Gas Chromatography/Mass Spectrometry (GC/MS)
  • Dimensions (L x W x H) 33.7 x 33.7 x 40 cm (includes batteries, carrier gas, and vacuum system)
  • Weight 16.3 kg (includes batteries, carrier gas, and vacuum system)
  • Operating Temp / Humidity 0 to 40 °C
  • Storage Temp -25 to 55 °C
  • Decontamination Sealed for Survey Mode operation in hot-zone; IP65-rated enclosure is dust-tight and spray-resistant
  • Power Supply 100-240V 50-60Hz (220 W max); 19V (DC); 2 x #2590 @ 15V Li Ion batteries (1 included)
  • Battery Life 4 hrs in Survey Mode, 2 hrs in Confirmation Mode; hot swappable
  • Start Up Time 15 minutes to full operation from cold
  • Calibrant Onboard FC-43 (Perfluorotributylamine)
  • Carrier Gas On-board helium; external helium connector, automatic switching (Hydrogen capable)
  • Display 9" Multitouch Color Display (1280x720 WVGA; 1300 nits brightness)
  • Alerts Audible and Visual (Touchscreen and Handheld Probe)
  • Software GSS Touch; multiple user levels
  • Communication 2 x USB 2.0, Bluetooth 4.0, WiFi 802.11n, Ethernet via USB, integrated GPS
  • Data Storage Internal 256GB SSD
  • Training Requirements 2 hours basic operation; 8 hours expert user
  • Sample Phase Solid, liquid, and vapor
  • Threats Detects and identifies explosives, narcotics, CWAs, TICs, environmental pollutants, and other chemicals
  • Standard Reference Database NIST/EPA/NIH Mass Spectral Library
  • Sampling & Analysis Full identification in 4-15 mins for most chemicals; near real-time in Survey Mode
  • Mass Analyzer Type Linear quadrupole mass filter
  • Mass Range / Resolution 15-515 m/z; 0.7 amu @ FWHM
  • Ionization Type / Source Electron Impact Ionization; non-radioactive ionization source
  • Detector Electron Multiplier
  • Vacuum System Self-contained miniature turbomolecular & diaphragm pumps
  • Dynamic Range 7 decades
  • Detection Limit PPM – PPT
  • LTM-GC Column DB-5MS (15 m x 0.18 mm x 0.25 μm); others available
  • Temperature Range Programmable 40 to 300 °C; ramping of 100 °C/min
Enlarged product image


For product inquiries or if the item you require is not listed, please contact our team directly.

Contact Us